THE BEARING CAPACITY AND FIRE RESISTANCE OFWOODEN BEAMS REINFORCED WITH EXTERNAL TAPE ARMATURE

  • O. Bashynskyy Lviv State University of Life Safety
  • Т. Вodnarchuk Lviv National Agrarian University
  • M. Peleshko Lviv State University of Life Safety
Keywords: wood structure, a metal tape reinforcement, fire resistance limit, fire resistance

Abstract

Article is devoted to the reinforcement of wooden structures. On the basis of experimental studies it was shown that the wooden beams reinforced with metal tape allows to increase their bearing capacity. The most effective way of reinforcing wooden beams reinforcement tape is to set it vertically in the plane of action of bending moment. Integrated use of flame retardant solutions for wood and metal will increase the fire resistance limit of the proposed structures to 30 minutes.

Downloads

Download data is not yet available.
Published
2018-10-12
How to Cite
Bashynskyy, O., ВodnarchukТ., & Peleshko, M. (2018). THE BEARING CAPACITY AND FIRE RESISTANCE OFWOODEN BEAMS REINFORCED WITH EXTERNAL TAPE ARMATURE. Bulletin of Lviv State University of Life Safety, 9, 184-189. Retrieved from https://journal.ldubgd.edu.ua/index.php/Visnuk/article/view/560